Tohari, Ma’ruf (2025) PERBANDINGAN PENURUNAN DAN DAYA DUKUNG TIANG PANCANG TUNGGAL BERDASARKAN METODE MAYERHOFF, PDA TEST, DAN SOFTWARE ALLPILE (Studi Kasus: Proyek Pembangunan Gedung Fakultas Kedokteran Universitas Katolik Soegijapranata Semarang). Undergraduate thesis, Universitas 17 Agustus 1945 Semarang.
Repository_MA'RUF TOHARI_SIPIL A - 1458_Ma'ruf Tohari.pdf
Download (358kB)
ma'aruf tohari - lembar konsultasi.pdf
Download (309kB)
Abstract
ABSTRAK
Pondasi tiang pancang berfungsi untuk mentransfer beban struktur ke lapisan tanah keras pada kedalaman tertentu dan sangat penting dalam konstruksi bangunan bertingkat. Penelitian ini bertujuan menganalisis penurunan dan daya dukung tiang pancang tunggal pada Proyek Pembangunan Gedung Fakultas Kedokteran Universitas Katolik Soegijapranata Semarang dengan menggunakan tiga metode, yaitu metode Mayerhoff, Allpile, dan pengujian dinamis PDA (Pile Driving Analyzer). Data yang digunakan meliputi hasil penyelidikan tanah, gambar perencanaan pondasi, dan hasil uji PDA di lapangan. Hasil analisis menunjukkan daya dukung ultimit metode Mayerhoff sebesar 243,312 ton, analisis dengan Allpile menghasilkan daya dukung maksimum sebesar 255,479 ton, sedangkan hasil pengujian PDA menunjukkan daya dukung sebesar 244,9 ton. Hasil perbandingan yang mendekati hasil PDA adalah metode Mayerhoff dengan selisih lebih kecil 0,64% dan Allpile dengan selisih lebih besar 4,31%.
Penurunan pondasi berdasarkan metode Mayerhoff adalah sebesar 14,00 mm, PDA test sebesar 18,9 mm dan Allpile sebesar 7,82 mm masih dalam batas aman menurut standar. Perbandingan hasil ketiga metode menunjukkan bahwa pondasi yang direncanakan telah memenuhi persyaratan teknis dari segi kekuatan dan kestabilan. Hasil ini menegaskan pentingnya validasi antara metode analisis dan pengujian lapangan untuk menjamin kinerja pondasi secara optimal.
Kata kunci: daya dukung tiang; penurunan; Mayerhoff; Allpile; PDA
===============================================================
ABSTRACT
Pile foundations serve to transfer structural loads to hard soil layers at a certain depth and are very important in the construction of multi-storey buildings. This study aims to analyze the settlement and bearing capacity of single piles in the Construction Project of the Faculty of Medicine, Soegijapranata Catholic University Semarang using three methods, namely the Mayerhoff method, Allpile, and dynamic PDA (Pile Driving Analyzer) testing. The data used include the results of soil investigations, foundation planning drawings, and PDA test results in the field. The analysis results show that the ultimate bearing capacity of the Mayerhoff method is 243.312 tons, the analysis with Allpile produces a maximum bearing capacity of 255.479 tons, while the PDA test results show a bearing capacity of 244.9 tons. The comparison results that are closest to the PDA results are the Mayerhoff method with a smaller difference of 0.64% and Allpile with a larger difference of 4.31%. The settlement of the foundation based
on the Mayerhoff method is 14.00 mm, PDA test of 18.9 mm, and Allpile is 7.82 mm, which is still within the safe limit according to standards. A comparison of the results of the three methods shows that the planned foundation meets the technical requirements for strength and stability. These results underscore the importance of validating the analysis method and field testing to ensure optimal foundation performance.
Keywords: pile bearing capacity; settlemet; Mayerhoff; Allpile; PDA
| Item Type: | Thesis (Undergraduate) |
|---|---|
| Uncontrolled Keywords: | daya dukung tiang; penurunan; Mayerhoff; Allpile; PDA |
| Subjects: | T Technology > TA Engineering (General). Civil engineering (General) T Technology > TH Building construction |
| Divisions: | Fakultas Teknik > 22201 - S1 Teknik Sipil |
| Depositing User: | Fakultas Teknik |
| Date Deposited: | 04 Sep 2025 07:20 |
| Last Modified: | 09 Jan 2026 03:31 |
| URI: | http://repository.untagsmg.ac.id/id/eprint/2315 |